SPEKTRUM+ SEPARATOR (Freefall System)
- For color sorting and separation of impurities out of glass cullet
- Applicable for container and flat glass recycling
- Suitable for dry and wet input material


COLOR – SORTING

Color Sorted Flint Glass

Color Sorted Green Glass

Color Sorted Amber Glass

CSP (Ceramic, Stones, Porcelain) and other non-transparent impurities like wood, plastics, metals, organic a.s.o.

Pb (leaded glass) e.g. lead crystal glass, CRT glass a.s.o.

HR (heat resistant glass) e.g. glass ceramic a.s.o.

Special glasses e.g. opal glass, coated glasses, tinted glasses a.s.o.

Ferrous (FE) and non-Ferrous (NE) metals e.g. aluminum caps, rings, parts of rings and caps, crown caps, wired glass, other metals like stainless steel, copper, brass, lead and other small metal pieces approx. > Ø 1,5mm (smaller pieces on request)
AVAILABLE SENSOR SYSTEMS
| SPEKTRUM+ FLASH sensor systems* | Detection of: |
| C | COLORS and CSP |
| C-C | Improved (CSP-)detection (e.g. for differentiation of Dark-Glass from CSP) |
| X | HR (heat resistant Glass) |
| Fo | Pb (leaded Glass) |
| M | METALS (Ferrous and non-Ferrous) |
* Most of the sensor systems for the SPEKTRUM+ FLASH separators can be combined and are upgradable in one Sorter, e.g. SPEKTRUM+ FLASH MXC-Fo.
AVAILABLE WORKING WIDTHS AND VALVE GRIDS
| Working width | Max. throughput capacity* | Number of valves [Valve distance] | |
| 1024 mm | 10 t/h | 320 [3,2 mm] | 160 [6,4 mm] |
| 1280 mm | 13 t/h | 320 [4,0 mm] | 160 [8,0 mm] |
| 1536 mm | 15 t/h | 384 [4,0 mm] | 240 [6,4 mm] |
* Depending on the amount of impurities and cullet size.
FEATURES
- High detection accuracy even with fine glass
- Precise separation
High-speed magnetic valves with extremely precise and fast switching times and a long working life ensure a precise separation of colors and impurities. - Lowest glass loss
Avoidance of false detection due to intelligent image processing algorithms. - Black glass detection
The optional dual-sensor system C-C improves the detection of CSP and allows e.g. a differentiation between extremely dark cullet (e.g. black glass) and CSP. The option C-C is also used for CSP detection in the fine glass fraction and other difficult sorting tasks. - Suitable for dry and wet input material
Due to the freefall-system the SPEKTRUM+ Separators work even well for wet cullet. - Modular multi-sensor system
All sensor systems for colors and impurities can optionally be integrated into a single SPEKTRUM+ FLASH Separator. All sensor systems can be retrofitted to the FLASH version.
As entry level separator we offer the SPEKTRUM+ BASIC Separator. The SPEKTRUM+ BASIC Separator can only be equipped with the C and M sensor systems and cannot be upgraded.